Innovating Works

SpreadMRI

Financiado
Ultra Fast Spread Spectrum Magnetic Resonance Imaging
Imaging speed is a key factor to capture rapid changes at high spatial and temporal resolution. A major limitation of magnetic resonance (MR) imaging is its rather low speed compared to other modalities like ultra sound or compute... Imaging speed is a key factor to capture rapid changes at high spatial and temporal resolution. A major limitation of magnetic resonance (MR) imaging is its rather low speed compared to other modalities like ultra sound or computerized tomography. We aim to explore two novel concepts to boost MR imaging speed by another order of magnitude compared to existing techniques. SpreadMRI fundamentally steps beyond current concepts of image encoding by exploiting a spectral spin modulation that so far has not been utilized. SpreadMRI is based on the rapid and local modulation of magnetic fields produced by current loops and/or radiofrequency (RF) loops. Applied spectral modulations are in the MHz range bridging the low-frequency band of switched gradients (kHz) and the 100 MHz range of the Larmor frequency. SpreadMRI spreads the bandwidth of gradient-encoded spin frequencies using distinct carrier frequencies originating from a certain region of the object. This spatially unique information will then be used to disentangle parts of the object, and thus to drastically boost imaging speed. Approaching this intermediate frequency band requires to address several basic research questions related to image reconstruction, electromagnetic coupling, spin Physics and possible biological effects. Based on theoretical analysis and exhaustive electromagnetic simulations of dedicated current loop and RF coil arrangements, including variants of different modulation patterns, several types of SpreadMRI coils for human head imaging at 9.4T will be developed and applied for high temporal and spatial functional brain imaging. The specific approach of SpreadMRI will lead to major changes in the hard- and software environment of current MR-scanners. It will not only provide new insight within the areas covered by the proposal, but will definitely benefit conventional MR diagnostic by enabling new applications with a simultaneous reduction of motion artifacts and increased patient throughput. ver más
28/02/2026
MPG
3M€
Duración del proyecto: 79 meses Fecha Inicio: 2019-07-26
Fecha Fin: 2026-02-28

Línea de financiación: concedida

El organismo H2020 notifico la concesión del proyecto el día 2019-07-26
Línea de financiación objetivo El proyecto se financió a través de la siguiente ayuda:
ERC-2018-ADG: ERC Advanced Grant
Cerrada hace 6 años
Presupuesto El presupuesto total del proyecto asciende a 3M€
Líder del proyecto
MAXPLANCKGESELLSCHAFT ZUR FORDERUNG DER WISSE... No se ha especificado una descripción o un objeto social para esta compañía.
Perfil tecnológico TRL 4-5