OPTImization of the automated Fitting to Outcomes eXpert with language independe...
OPTImization of the automated Fitting to Outcomes eXpert with language independent hearing in noise test battery and electro acoustical test box for cochlear implant users
Patients suffering from sensori-neural hearing loss caused by damaged hair cells in the cochlea and diagnosed as being profoundly deaf, are potential candidates for cochlear implantation. Today, there are a number of important lim...
ver más
¿Tienes un proyecto y buscas un partner? Gracias a nuestro motor inteligente podemos recomendarte los mejores socios y ponerte en contacto con ellos. Te lo explicamos en este video
FFI2015-68498-P
EL DESARROLLO LINGUISTICO DEL NIÑO SORDO CON IMPLANTE COCLEA...
30K€
Cerrado
OPERA
Road to Market for Fully Implantable Cochlear Implant Phase...
150K€
Cerrado
Información proyecto OPTI-FOX
Líder del proyecto
OTOCONSULT NV
No se ha especificado una descripción o un objeto social para esta compañía.
TRL
4-5
Presupuesto del proyecto
2M€
Fecha límite de participación
Sin fecha límite de participación.
Descripción del proyecto
Patients suffering from sensori-neural hearing loss caused by damaged hair cells in the cochlea and diagnosed as being profoundly deaf, are potential candidates for cochlear implantation. Today, there are a number of important limitations with respect to the optimal use of these devices in deaf patients. Firstly, cochlear implant speech processors need to be adjusted so that sounds perceived by the patient are representational and at a comfortable level. Manual fitting, currently the norm, is technically demanding and time consuming and clearly suboptimal, as it involves only two of the many electrical parameters in the speech processor. Secondly, manipulation of the implant settings is based on subjective judgments of the patient , which are often inconsistent and do not reflect the outcomes on psychoacoustic measures. For the last few years, experts in the field have expressed the need for a new fitting process that optimizes the patient’s hearing in a more efficient and accurate way. For this to happen, the fitting procedure should change from a comfort-driven approach to an outcome-driven one. It should also address as many electrical parameters as possible. Ideally, a cochlear implant should come with an assisted or (semi-)automated fitting procedure in which a large number of parameters may be adjusted, based on measured psycho-acoustic feedback from the implant user. Such an assisted fitting process would drastically reduce the number of man-hours of fitting during the lifetime of the device with qualitative with qualitatively better outcomes. The main objectives of the proposed research project are therefore (i) to turn an existing theoretical automated fitting model into a clinical application by means of various techniques from statistics, machine learning and optimisation; (ii) to develop an evaluation tool to measure functional hearing capacities, in casu the ability to understand speech-in-noise, representative for day-to-day listening situations.