Development of new immunoassays for the diagnosis and prediction of drug related...
Development of new immunoassays for the diagnosis and prediction of drug related complement pathology
Infusion reactions (IRs) are complex, immune-mediated side effects, also known as hypersensitivity reactions (HSRs), that can occur upon intravenous infusion of pharmaceuticals, leading to severe and sometimes life-threatening con...
ver más
¿Tienes un proyecto y buscas un partner? Gracias a nuestro motor inteligente podemos recomendarte los mejores socios y ponerte en contacto con ellos. Te lo explicamos en este video
Información proyecto immunoassays
Duración del proyecto: 24 meses
Fecha Inicio: 2020-03-05
Fecha Fin: 2022-03-31
Líder del proyecto
TECODEVELOPMENT GMBH
No se ha especificado una descripción o un objeto social para esta compañía.
TRL
4-5
Presupuesto del proyecto
175K€
Fecha límite de participación
Sin fecha límite de participación.
Descripción del proyecto
Infusion reactions (IRs) are complex, immune-mediated side effects, also known as hypersensitivity reactions (HSRs), that can occur upon intravenous infusion of pharmaceuticals, leading to severe and sometimes life-threatening conditions in patients. Those reactions may arise from a real allergy which is immune globulin class E (IgE) mediated or a pseudoallergy. The latter involves no IgEs and may arise because of activation of the complement (C) system called C activation-related pseudoallergy (CARPA). The complement (C-) system is part of the immune system called the innate immune system that is not adaptable and responds to foreign challenges in a non-specific manner. When stimulated proteases of the complement system cleave other C proteins and initiate an amplifying cascade of further cleavages. The end-result of this activation cascade is a massive acute inflammatory response caused by the release of cytokines, anaphylatoxins and the cell-killing membrane attack complex (MAC). Products triggering severe adverse events can include both traditional small molecules but also biologics such as therapeutic antibodies (Abs), fusion proteins, etc. and novel formulations using liposomes or nanotechnology. Regulatory guidance on the assessment of C-mediated infusion hypersensitivity has been published recently for the case of generic liposome production. Hemocompatibility (blood safety) testing for medical devices is requested by EMA and FDA since many years. However, regarding the potential of new pharmaceuticals causing allergies and/or CARPA remains a significant challenge for the industry during nonclinical development as no established safety biomarker nor meaningful, validated animal models are available up to date. During the project IMMUNOASSAYS Dr Fülöp proposes the development and quantitative evaluation of three promising specific safety biomarkers via ELISA technology.