Out-of-field neutron dosimetry for FLASH therapy based on SiC sensors
Cancer is a major public health problem worldwide. According to the latest research, 20% of people will develop cancer at some point during their lifetime. Radiotherapy (RT) is the medical use of ionizing radiation to treat cancer...
Cancer is a major public health problem worldwide. According to the latest research, 20% of people will develop cancer at some point during their lifetime. Radiotherapy (RT) is the medical use of ionizing radiation to treat cancer. About 52% of cancer patients receive RT at least once during their treatment. During the last years, new RT treatment modalities are rapidly being researched, one of the most promising is the Ultra High Dose-Rate Radiotherapy (UHDR) or FLASH therapy, where the delivered dose rate is several orders of magnitude higher than the conventional one. This approach has been found to elicit significant sparing of healthy tissues with equal probability of tumor control. One of the challenges to validate and enable the clinical implementation of FLASH is the development of active dosimetry systems that allow accurate dose measurements and beam monitoring.
The experience gained in RT traditional treatments shows that secondary neutrons can produce a not insignificant undesirable parasitic dose to healthy tissue and critical organs that can induce late effects. Therefore, the measurement of neutron flux and its spectrum is key to determining potential risks in FLASH therapy. The goal of this project is the development of a novel matrix of active neutron dosimeters based on Silicon Carbide (SiC) diodes covered with different types of neutron conversion layers and moderators for characterizing the neutron contribution out-of-field in FLASH conditions. SiC has many advantages, e.g., low noise, insensitivity to visible light and temperature variations, higher radiation hardness than silicon. The host group has been the first worldwide in obtaining a SiC detector with a linear relationship between the charge collected and the dose up to 11 Gy/pulse (1.5 um pulse). To the best of our knowledge, there are no active neutron dosimeters to measure out-of-field neutron doses in FLASH conditions. We propose to create the first one in the field.ver más
15-11-2024:
PERTE CHIP IPCEI ME/...
Se ha cerrado la línea de ayuda pública: Ayudas para el impulso de la cadena de valor de la microelectrónica y de los semiconductores (ICV/ME)
15-11-2024:
REDES
En las últimas 48 horas el Organismo REDES ha otorgado 1579 concesiones
15-11-2024:
DGIPYME
En las últimas 48 horas el Organismo DGIPYME ha otorgado 3 concesiones
Seleccionando "Aceptar todas las cookies" acepta el uso de cookies para ayudarnos a brindarle una mejor experiencia de usuario y para analizar el uso del sitio web. Al hacer clic en "Ajustar tus preferencias" puede elegir qué cookies permitir. Solo las cookies esenciales son necesarias para el correcto funcionamiento de nuestro sitio web y no se pueden rechazar.
Cookie settings
Nuestro sitio web almacena cuatro tipos de cookies. En cualquier momento puede elegir qué cookies acepta y cuáles rechaza. Puede obtener más información sobre qué son las cookies y qué tipos de cookies almacenamos en nuestra Política de cookies.
Son necesarias por razones técnicas. Sin ellas, este sitio web podría no funcionar correctamente.
Son necesarias para una funcionalidad específica en el sitio web. Sin ellos, algunas características pueden estar deshabilitadas.
Nos permite analizar el uso del sitio web y mejorar la experiencia del visitante.
Nos permite personalizar su experiencia y enviarle contenido y ofertas relevantes, en este sitio web y en otros sitios web.