PALPABLE introduces a new generation of MIS (Minimally Imvasive Surgery) tools: a novel tactile sensing probe as a palpation tool for identification and visualization of tissue abnormalities. MIS has several advantages (reduced ti...
PALPABLE introduces a new generation of MIS (Minimally Imvasive Surgery) tools: a novel tactile sensing probe as a palpation tool for identification and visualization of tissue abnormalities. MIS has several advantages (reduced tissue damage, postoperative analgesic requirements & blood loss, decreased hospitalization time, better cosmetic results), but there is limited or none visual, haptic, and tactile feedback in-situ, along with issues of tool dexterity. These issues can lead to accidental tissue damage. The probe (diam. 5mm, length 15-20mm) incorporates multiple sensing modalities and a thin, flexible, pneumatically actuated end-effector (3DOF, 180deg) with distributed sensors for distributed tactile sensing. The probe consists of the photonic sensing elements and a sphere held at the end of a circular tunnel by a steady flow of air. The sphere is free to rotate in all directions and can move into the channel when pressed against the airflow. When rolling over tissue, the displacement depends on the tissue’s stiffness and is picked up by the optical fibre above it. Optical intensity variation in the sensing element is used to identify tissue stiffness variations. The principle of measurement used is extrinsic light intensity modulation provided through optical fibres. A non-planar photonics circuit (200μm waveguide, 8bit colour depth) for haptic sensor array is developed and interfaced with the probe; this circuit will be engraved on ultra-thin polymeric foil. The foil sensing elements are distributed around & along the probe for multiple sensor inputs for palpation (i.e., stiffness), distance and curvature that are then fused to provide the overall tissue situation. Using thin foils allows for ease of integration with the probe and a straightforward manufacturing process to enable low cost in large volumes. The end effector is made from disposable or sterilizable materials, both options will be explored for recyclability or reusability respectively.ver más
02-11-2024:
Generación Fotovolt...
Se ha cerrado la línea de ayuda pública: Subvenciones destinadas al fomento de la generación fotovoltaica en espacios antropizados en Canarias, 2024
01-11-2024:
ENESA
En las últimas 48 horas el Organismo ENESA ha otorgado 6 concesiones
01-11-2024:
FEGA
En las últimas 48 horas el Organismo FEGA ha otorgado 1667 concesiones
Seleccionando "Aceptar todas las cookies" acepta el uso de cookies para ayudarnos a brindarle una mejor experiencia de usuario y para analizar el uso del sitio web. Al hacer clic en "Ajustar tus preferencias" puede elegir qué cookies permitir. Solo las cookies esenciales son necesarias para el correcto funcionamiento de nuestro sitio web y no se pueden rechazar.
Cookie settings
Nuestro sitio web almacena cuatro tipos de cookies. En cualquier momento puede elegir qué cookies acepta y cuáles rechaza. Puede obtener más información sobre qué son las cookies y qué tipos de cookies almacenamos en nuestra Política de cookies.
Son necesarias por razones técnicas. Sin ellas, este sitio web podría no funcionar correctamente.
Son necesarias para una funcionalidad específica en el sitio web. Sin ellos, algunas características pueden estar deshabilitadas.
Nos permite analizar el uso del sitio web y mejorar la experiencia del visitante.
Nos permite personalizar su experiencia y enviarle contenido y ofertas relevantes, en este sitio web y en otros sitios web.