Electrochemical Graphene Sensors as Early Alert Tools for Algal Toxin Detection...
Electrochemical Graphene Sensors as Early Alert Tools for Algal Toxin Detection in Water
Episodes of harmful blue algae blooms and the associated algal toxin microcystin-LR (MC-LR) occur frequently in bodies of water worldwide as consequences of eutrophication resulting from anthropogenic activities such as agricultur...
ver más
¿Tienes un proyecto y buscas un partner? Gracias a nuestro motor inteligente podemos recomendarte los mejores socios y ponerte en contacto con ellos. Te lo explicamos en este video
Proyectos interesantes
PON-SXT
Development of a Sustainable, Low-cost and Long-term Lab-on-...
Cerrado
BES-2015-074635
MICROSISTEMAS PARA LA DETECCION RAPIDA, FIABLE Y RENTABLE DE...
93K€
Cerrado
SMS
Sensing toxicants in Marine waters makes Sense using biosens...
6M€
Cerrado
OMEGA
Online Monitoring Electrochemiluminescence based Gated Assa...
163K€
Cerrado
SEA-ON-A-CHIP
Real time monitoring of SEA contaminants by an autonomous La...
8M€
Cerrado
CTQ2009-14390-C02-02
DESARROLLO DE TRANSDUCTORES BASADOS EN PILAS MICROBIANAS DE...
115K€
Cerrado
Información proyecto GrapheneBiosensor
Duración del proyecto: 31 meses
Fecha Inicio: 2017-03-21
Fecha Fin: 2019-11-07
Líder del proyecto
SWANSEA UNIVERSITY
No se ha especificado una descripción o un objeto social para esta compañía.
TRL
4-5
Presupuesto del proyecto
195K€
Fecha límite de participación
Sin fecha límite de participación.
Descripción del proyecto
Episodes of harmful blue algae blooms and the associated algal toxin microcystin-LR (MC-LR) occur frequently in bodies of water worldwide as consequences of eutrophication resulting from anthropogenic activities such as agricultural run-off, urban waste, and manufacturing of detergents and global warming. It had been confirmed that microcystins were responsible for some poisonings of animals and humans where water sources contained toxic cyanobacteria blooms. Microcystins were potent and specific in inhibiting protein phosphatases 1 and 2A (PPl, PP2A). Acute or prolonged exposure to microcystins would cause liver damage, followed by a massive intrahepatic hemorrhage and probably leading to death. In 1998, the provisional guideline concentration limit of 1 μg/L MC-LR in drinking water was assigned by the World Health Organization (WHO). The development of reliable methods for monitoring MC-LR in water resources is of great interest to determine the occurrence and to prevent exposure to the toxin. Several methods have been developed to detect MC-LR, such as high-performance liquid chromatography/mass spectrometry (HPLC/MS) , bio-, biochemical- and immune-assays, which require long processing times, sophisticated instruments, complex procedures, or high processing cost and are in general used in the laboratory, not in situ. A sensitive, specific, simple, and rapid method for monitoring MC-LR could help to prevent exposure to the toxin. The unique physical and electrochemical properties (e.g., high electrical conductivity, ease of functionalization, high electrochemically active surface area, and broad range of working potentials in aqueous solutions) of graphene make them a candidate material for developing novel and fit-for-purpose electrochemical biosensors/immunosensors as alternatives to the time-consuming, expensive, non-portable and often skills-demanding conventional methods of analysis involved in water quality assessment.