Development of a cost effective anti bacterial device for the 37 million urethra...
Development of a cost effective anti bacterial device for the 37 million urethral catheters used in enlarged Europe
A survey conducted by WHO showed that 2,4 million of European patients suffer nosocomial infections every year. Urinary Tract Infections (UTI) account for approximately 40% of nosocomial infections; 80% of UTIs are associated with...
ver más
¿Tienes un proyecto y buscas un partner? Gracias a nuestro motor inteligente podemos recomendarte los mejores socios y ponerte en contacto con ellos. Te lo explicamos en este video
Proyectos interesantes
NANOELAST
Next Generation Urinary Catheters for Preventing Catheter As...
71K€
Cerrado
RTC-2017-6668-1
Desarrollo catéter urinario antibacteriano - Bio-Urostent
128K€
Cerrado
SAF2017-82251-R
NUEVAS ESTRATEGIAS DE PREVENCION Y DIAGNOSTICO DE LAS INFECC...
133K€
Cerrado
Información proyecto SAFE CATHETER
Líder del proyecto
RINA CONSULTING SPA
No se ha especificado una descripción o un objeto social para esta compañía.
TRL
4-5
Presupuesto del proyecto
1M€
Fecha límite de participación
Sin fecha límite de participación.
Descripción del proyecto
A survey conducted by WHO showed that 2,4 million of European patients suffer nosocomial infections every year. Urinary Tract Infections (UTI) account for approximately 40% of nosocomial infections; 80% of UTIs are associated with the use of indwelling urethral catheters. UTIs related to indwelling catheterisation prolong the mean length of hospitalisation, ranging from 2.4 to 19.8 days; 2 Billion Euro is the associated annual direct cost for National Health Services. Furthermore catheter associated UTIs are responsible for increased hospital mortality; the infection proves in fact fatal for around 30,000 people in Europe every year. Two routes of entry of uropathogens to catheterized urinary tracts exist: 1) extraluminal contamination may occur early, by direct inoculation when the catheter is inserted, or more frequently, by organisms ascending from the perineum by capillary action in the thin mucous film contiguous to the external catheter surface; 2) intraluminal contamination occurs by reflux of microorganisms gaining access to the catheter lumen from failure of closed drainage or contamination of urine in the collection bag. While extraluminal infection route was blocked by coating the external catheter walls with hydrogel-silver films that reproduce the natural barrier mechanism of urethra physiology, no effective solution exists today to avoid intraluminal infections. The overall objective of the project is to develop a cost-effective device able to create a barrier that avoids migration of the bacteria intraluminally. The proposed concept is based on a plastic cage whose internal walls are covered with a thin film of photocatalytic TiO2 (anatase), triggered by inexpensive low energy UV LEDs powered by coin cells commercially available for watches or calculators. The concept addresses the limitations of current approaches